Interfacing BU-70 Display Units and BU-100/BU-101 Panels AutroSafe BU-70 Interfa
Description 2.4 Indicators and buttons / Language selection = Switch in ON position Interfacing BU70 Display Units and BU100/BU101 Panels, A
Description 2.5 Connectors The plug-in screw terminals are numbered 1 – 32. Interfacing BU70 Display Units and BU100/BU101 Panels, AutroSafe Interac
Installation Interfacing BU70 Display Units and BU100/BU101 Panels, AutroSafe Interactive Fire-Alarm System, 116-P-BSL337/EE, Rev. D, 2007-01-25,
Installation 3.3 Installation Overview - up to 16 BU-panels The following system blocks are referred to in this overview: EAU-321 AutroSafe Serial
Installation 3.4 Installation Overview - more than 16 BU-panels The following system blocks are referred to in this overview: EAU-321 AutroSafe S
Installation 3.5 Installation Overview – star-connection using a communication line splitter The following system blocks are referred to in th
Installation 3.6 Standard Communication Parameters The BSL-337 is delivered from the factory containing the following communication parameters: • Po
Installation 3.7.1 Jumper Settings — EAU-321 Port 4Port 3Port 1Port 2J5J6J7J8J9J10J11Interfacing BU70 Display Units and BU100/BU101 Panels, AutroSafe
Installation 3.7.2 Termination by use of ribbon cable and standard screw terminal block EAU-321J3XGK-1/20-30Port 1 and 2242013195 (Tx)9 (GND)3 (Rx)Te
Installation 3.8 RS-232 / Current Loop Communication 3.8.1 Overview The following system blocks are referred to in this overview: EAU-321 AutroSaf
COPYRIGHT © This publication, or parts thereof, may not be reproduced in any form, by any method, for any purpose. Autronica Fire and Security AS an
Installation Interfacing BU70 Display Units and BU100/BU101 Panels, AutroSafe Interactive Fire-Alarm System, 116-P-BSL337/EE, Rev. D, 2007-01-25,
BSL_337 Installation 4. BSL_337 Installation The BSL-337 interface and RS-232/Current Loop Converter BSL-12/2 may be installed in one of two ways: in
BSL_337 Installation 4.2 Mounting and Connections Interfacing BU70 Display Units and BU100/BU101 Panels, AutroSafe Interactive Fire-Alarm System,
BSL_337 Installation 4.2.2 Mounting the Current Loop/RS-232 Converter BSL-12/2 The Current Loop/RS-232 Converter BSL-12/2 has configurable inputs and
BSL_337 Installation 4.2.4 Mounting the Communication Line Splitter KDL-26B The Communication Line Splitter KDL-26B is delivered as a separate circui
BSL_337 Installation 4.2.5 Connections between the Current Loop/RS-232 Converter and the Communication Line Splitter KDL-26B The Communica
Configuring the AutroSafe System 5. Configuring the AutroSafe System 5.1 Introduction AutroSafeConfigPowerFire Brig. recvd.Fire vent. activ.
Configuring the AutroSafe System • In the popup menu that appears, write the name of unit to be added, and state the number of units to be added
Configuring the AutroSafe System • Select port number, 1 or 2. • Verify the parameter settings (baud rate to 9 600 baud, 8 bits, none parity, 1
Configuring BSL_337 6. Configuring BSL_337 6.1 Settings on the Panel Front / Language selection = Switch in ON position The DIP-switches and
Table of Contents Interfacing BU70 Display Units and BU100/BU101 Panels, AutroSafe Interactive Fire-Alarm System, 116-P-BSL337/EE, Rev. D, 2007-01-2
Configuring BSL_337 Interfacing BU70 Display Units and BU100/BU101 Panels, AutroSafe Interactive Fire-Alarm System, 116-P-BSL337/EE, Rev. D, 2007-0
Configuring BSL_337 Interfacing BU70 Display Units and BU100/BU101 Panels, AutroSafe Interactive Fire-Alarm System, 116-P-BSL337/EE, Rev. D, 2007-01
Testing BSL_337 7. Testing BSL_337 In order to verify that alarms, prealarms and faults are transmitted from the BSL-337 interface, complete a simple
Testing the Final Installation 8. Testing the Final Installation When the installation is completed, verify that all BU-panels show alarms, prealarms
Appendix Interfacing BU70 Display Units and BU100/BU101 Panels, AutroSafe Interactive Fire-Alarm System, 116-P-BSL337/EE, Rev. D, 2007-01-25, Autr
Appendix Interfacing BU70 Display Units and BU100/BU101 Panels, AutroSafe Interactive Fire-Alarm System, 116-P-BSL337/EE, Rev. D, 2007-01-25, Autro
Reader’s Comments Interfacing BU70 Display Units and BU100/BU101 Panels, AutroSafe Interactive Fire-Alarm System, 116-P-BSL337/EE, Rev. D, 2007-01-
Reader’s Comments Interfacing BU70 Display Units and BU100/BU101 Panels, AutroSafe Interactive Fire-Alarm System, 116-P-BSL337/EE, Rev. D, 2007-01-
Table of Contents Interfacing BU70 Display Units and BU100/BU101 Panels, AutroSafe Interactive Fire-Alarm System, 116-P-BSL337/EE, Rev. D, 2007-01-
Autronica Fire and Security AS is an international company, based in Trondheim, Norway, and has a world-wide sales and service network. For more th
Introduction Interfacing BU70 Display Units and BU100/BU101 Panels, AutroSafe Interactive Fire-Alarm System, 116-P-BSL337/EE, Rev. D, 2007-01-25, A
Introduction Interfacing BU70 Display Units and BU100/BU101 Panels, AutroSafe Interactive Fire-Alarm System, 116-P-BSL337/EE, Rev. D, 2007-01-25,
Description Interfacing BU70 Display Units and BU100/BU101 Panels, AutroSafe Interactive Fire-Alarm System, 116-P-BSL337/EE, Rev. D, 2007-01-25, Au
Description 2.1.4 Printer support Note that the printer function on the BU-100 Parallel Operation Panel is not supported by using the BSL-337 interfac
Description Interfacing BU70 Display Units and BU100/BU101 Panels, AutroSafe Interactive Fire-Alarm System, 116-P-BSL337/EE, Rev. D, 2007-01-25, Au